{"history":[{"alert":0,"cve":"CVE-2023-6448","id":22625,"kind":"epss","observed_at":1794500401,"payload":"{\"date\": \"2026-11-12\", \"epss\": 0.02089, \"percentile\": 0.81874}"},{"alert":0,"cve":"CVE-2023-6448","id":20244,"kind":"epss","observed_at":1794327601,"payload":"{\"date\": \"2026-11-10\", \"epss\": 0.02089, \"percentile\": 0.81759}"},{"alert":0,"cve":"CVE-2023-6448","id":18211,"kind":"epss","observed_at":1794241201,"payload":"{\"date\": \"2026-11-09\", \"epss\": 0.02089, \"percentile\": 0.81737}"},{"alert":0,"cve":"CVE-2023-6448","id":16275,"kind":"epss","observed_at":1794154800,"payload":"{\"date\": \"2026-11-08\", \"epss\": 0.02089, \"percentile\": 0.81728}"},{"alert":0,"cve":"CVE-2023-6448","id":14253,"kind":"epss","observed_at":1794068402,"payload":"{\"date\": \"2026-11-07\", \"epss\": 0.02089, \"percentile\": 0.81714}"},{"alert":0,"cve":"CVE-2023-6448","id":12035,"kind":"epss","observed_at":1793982001,"payload":"{\"date\": \"2026-11-06\", \"epss\": 0.02089, \"percentile\": 0.81684}"},{"alert":0,"cve":"CVE-2023-6448","id":10021,"kind":"epss","observed_at":1793938800,"payload":"{\"date\": \"2026-11-05\", \"epss\": 0.02089, \"percentile\": 0.81671}"},{"alert":0,"cve":"CVE-2023-6448","id":7569,"kind":"epss","observed_at":1793809200,"payload":"{\"date\": \"2026-11-04\", \"epss\": 0.02089, \"percentile\": 0.81659}"},{"alert":1,"cve":"CVE-2023-6448","id":6187,"kind":"cna","observed_at":1793809200,"payload":"{\"containers\": {\"adp\": [{\"providerMetadata\": {\"dateUpdated\": \"2024-08-02T08:28:21.839Z\", \"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\"}, \"references\": [{\"tags\": [\"government-resource\", \"x_transferred\"], \"url\": \"https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems\"}, {\"tags\": [\"x_transferred\"], \"url\": \"https://www.unitronicsplc.com/cyber_security_vision-samba/\"}, {\"tags\": [\"release-notes\", \"x_transferred\"], \"url\": \"https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf\"}, {\"tags\": [\"vendor-advisory\", \"x_transferred\"], \"url\": \"https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf\"}], \"title\": \"CVE Program Container\"}, {\"affected\": [{\"cpes\": [\"cpe:2.3:a:unitronics:visilogic:*:*:*:*:*:*:*:*\"], \"defaultStatus\": \"unknown\", \"product\": \"visilogic\", \"vendor\": \"unitronics\", \"versions\": [{\"lessThan\": \"9.9.00\", \"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\"}]}], \"metrics\": [{\"other\": {\"content\": {\"id\": \"CVE-2023-6448\", \"options\": [{\"Exploitation\": \"active\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"role\": \"CISA Coordinator\", \"timestamp\": \"2023-12-06T14:07:21.216497Z\", \"version\": \"2.0.3\"}, \"type\": \"ssvc\"}}, {\"other\": {\"content\": {\"dateAdded\": \"2023-12-11\", \"reference\": \"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448\"}, \"type\": \"kev\"}}], \"providerMetadata\": {\"dateUpdated\": \"2025-10-21T23:05:30.290Z\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\"}, \"references\": [{\"tags\": [\"government-resource\"], \"url\": \"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448\"}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2023-12-11T00:00:00.000Z\", \"value\": \"CVE-2023-6448 added to CISA KEV\"}], \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"affected\": [{\"defaultStatus\": \"unknown\", \"product\": \"VisiLogic\", \"vendor\": \"Unitronics\", \"versions\": [{\"lessThan\": \"9.9.00\", \"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\"}]}], \"datePublic\": \"2023-11-28T05:00:00.000Z\", \"descriptions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.<br>\"}], \"value\": \"Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.\"}], \"metrics\": [{\"cvssV3_1\": {\"attackComplexity\": \"LOW\", \"attackVector\": \"NETWORK\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"scope\": \"UNCHANGED\", \"userInteraction\": \"NONE\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"version\": \"3.1\"}, \"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"problemTypes\": [{\"descriptions\": [{\"cweId\": \"CWE-1188\", \"description\": \"CWE-1188 Insecure Default Initialization of Resource\", \"lang\": \"en\", \"type\": \"CWE\"}]}], \"providerMetadata\": {\"dateUpdated\": \"2023-12-19T16:23:39.022Z\", \"orgId\": \"9119a7d8-5eab-497f-8521-727c672e3725\", \"shortName\": \"cisa-cg\"}, \"references\": [{\"tags\": [\"government-resource\"], \"url\": \"https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems\"}, {\"url\": \"https://www.unitronicsplc.com/cyber_security_vision-samba/\"}, {\"tags\": [\"release-notes\"], \"url\": \"https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf\"}, {\"tags\": [\"vendor-advisory\"], \"url\": \"https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf\"}], \"source\": {\"discovery\": \"UNKNOWN\"}, \"title\": \"Unitronics VisiLogic uses a default administrative password\", \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}}}, \"cveMetadata\": {\"assignerOrgId\": \"9119a7d8-5eab-497f-8521-727c672e3725\", \"assignerShortName\": \"cisa-cg\", \"cveId\": \"CVE-2023-6448\", \"datePublished\": \"2023-12-05T17:43:40.451Z\", \"dateReserved\": \"2023-11-30T18:40:51.463Z\", \"dateUpdated\": \"2025-10-21T23:05:30.290Z\", \"state\": \"PUBLISHED\"}, \"dataType\": \"CVE_RECORD\", \"dataVersion\": \"5.1\"}"},{"alert":0,"cve":"CVE-2023-6448","id":5346,"kind":"epss","observed_at":1793722800,"payload":"{\"date\": \"2026-11-03\", \"epss\": 0.02089, \"percentile\": 0.81625}"},{"alert":0,"cve":"CVE-2023-6448","id":3128,"kind":"epss","observed_at":1793665375,"payload":"{\"date\": \"2026-11-02\", \"epss\": 0.02089, \"percentile\": 0.81605}"},{"alert":1,"cve":"CVE-2023-6448","id":716,"kind":"kev","observed_at":1793665375,"payload":"{\"cveID\": \"CVE-2023-6448\", \"cwes\": [\"CWE-1188\"], \"dateAdded\": \"2023-12-11\", \"dueDate\": \"2023-12-18\", \"forensicTriage\": \"No\", \"knownRansomwareCampaignUse\": \"Unknown\", \"notes\": \"Note that while it is possible to change the default password, implementors are encouraged to remove affected controllers from public networks and update the affected firmware: https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf;   https://nvd.nist.gov/vuln/detail/CVE-2023-6448\", \"product\": \"Vision PLC and HMI\", \"requiredAction\": \"Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.\", \"shortDescription\": \"Unitronics Vision Series PLCs and HMIs ship with an insecure default password, which if left unchanged, can allow attackers to execute remote commands.\", \"vendorProject\": \"Unitronics\", \"vulnerabilityName\": \"Unitronics Vision PLC and HMI Insecure Default Password Vulnerability\"}"}],"record":{"affected":[{"defaultStatus":"unknown","product":"VisiLogic","vendor":"Unitronics","versions":[{"lessThan":"9.9.00","status":"affected","version":"0","versionType":"custom"}]}],"cna":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-02T08:28:21.839Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["government-resource","x_transferred"],"url":"https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"},{"tags":["x_transferred"],"url":"https://www.unitronicsplc.com/cyber_security_vision-samba/"},{"tags":["release-notes","x_transferred"],"url":"https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"},{"tags":["vendor-advisory","x_transferred"],"url":"https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"}],"title":"CVE Program Container"},{"affected":[{"cpes":["cpe:2.3:a:unitronics:visilogic:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"visilogic","vendor":"unitronics","versions":[{"lessThan":"9.9.00","status":"affected","version":"0","versionType":"custom"}]}],"metrics":[{"other":{"content":{"id":"CVE-2023-6448","options":[{"Exploitation":"active"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2023-12-06T14:07:21.216497Z","version":"2.0.3"},"type":"ssvc"}},{"other":{"content":{"dateAdded":"2023-12-11","reference":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"},"type":"kev"}}],"providerMetadata":{"dateUpdated":"2025-10-21T23:05:30.290Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"references":[{"tags":["government-resource"],"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"}],"timeline":[{"lang":"en","time":"2023-12-11T00:00:00.000Z","value":"CVE-2023-6448 added to CISA KEV"}],"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"VisiLogic","vendor":"Unitronics","versions":[{"lessThan":"9.9.00","status":"affected","version":"0","versionType":"custom"}]}],"datePublic":"2023-11-28T05:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.<br>"}],"value":"Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1188","description":"CWE-1188 Insecure Default Initialization of Resource","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2023-12-19T16:23:39.022Z","orgId":"9119a7d8-5eab-497f-8521-727c672e3725","shortName":"cisa-cg"},"references":[{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"},{"url":"https://www.unitronicsplc.com/cyber_security_vision-samba/"},{"tags":["release-notes"],"url":"https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"},{"tags":["vendor-advisory"],"url":"https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"}],"source":{"discovery":"UNKNOWN"},"title":"Unitronics VisiLogic uses a default administrative password","x_generator":{"engine":"Vulnogram 0.1.0-dev"}}},"cveMetadata":{"assignerOrgId":"9119a7d8-5eab-497f-8521-727c672e3725","assignerShortName":"cisa-cg","cveId":"CVE-2023-6448","datePublished":"2023-12-05T17:43:40.451Z","dateReserved":"2023-11-30T18:40:51.463Z","dateUpdated":"2025-10-21T23:05:30.290Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"cna_checked":1794241201,"cve":"CVE-2023-6448","description":"Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.","epss":{"date":"2026-11-12","epss":0.02089,"percentile":0.81874},"epss_checked":1794522003,"first_seen":1793665375,"kev":{"cveID":"CVE-2023-6448","cwes":["CWE-1188"],"dateAdded":"2023-12-11","dueDate":"2023-12-18","forensicTriage":"No","knownRansomwareCampaignUse":"Unknown","notes":"Note that while it is possible to change the default password, implementors are encouraged to remove affected controllers from public networks and update the affected firmware: https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf;   https://nvd.nist.gov/vuln/detail/CVE-2023-6448","product":"Vision PLC and HMI","requiredAction":"Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.","shortDescription":"Unitronics Vision Series PLCs and HMIs ship with an insecure default password, which if left unchanged, can allow attackers to execute remote commands.","vendorProject":"Unitronics","vulnerabilityName":"Unitronics Vision PLC and HMI Insecure Default Password Vulnerability"},"kev_checked":1794522003,"products":"Unitronics VisiLogic","references":["https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems","https://www.unitronicsplc.com/cyber_security_vision-samba/","https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf","https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf","https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"],"score":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","provider":"cisa-cg","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"solutions":"","state":"PUBLISHED","title":"Unitronics VisiLogic uses a default administrative password","updated_at":1794500401,"workarounds":""},"sources":[]}
