November 13, 2026 Follow Egret
CVE-2026-109618 · CVE record: PUBLISHED

RCE via OOM corruption

PHP Group PHP

PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).

Exploitation evidence

Known exploited · CISA KEV listed

Added 2026-10-26. Ransomware campaign use: Unknown.

CISA required action: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

CISA due date: 2026-10-29. This is the catalog’s deadline, not an assessment of your organization’s exposure.

KEV checked 13 Nov 2026, 00:20 Jerusalem · Original catalog ↗

Reported products and versions

PHP Group / PHP

Default status: unaffected

  • affected: 8.2.* to < 8.2.35 (semver)
  • affected: 8.3.* to < 8.3.36 (semver)
  • affected: 8.4.* to < 8.4.27 (semver)
  • affected: 8.5.* to < 8.5.12 (semver)

Fixes and workarounds

No explicit solution text in the downloaded CVE record. Consult the vendor advisory; unaffected version ranges are shown above as reported, not inferred as a patch recommendation.

Reported workarounds: Check the GitHub Security Advisory for mitigation strategies.

Sources and related reporting

CVE Program record ↗ · Download tracked evidence as JSON

Monitored source mentions

Shared CVE identifiers link source mentions; they do not establish that the reports describe the same incident.

Observed change timeline

History begins when Egret first downloads each source. It is not the complete upstream CVE history.

12 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-12",
  "epss": 0.99999,
  "percentile": 0.99999
}
10 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-10",
  "epss": 0.99999,
  "percentile": 0.99999
}
09 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-09",
  "epss": 0.99999,
  "percentile": 0.99999
}
08 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-08",
  "epss": 0.99999,
  "percentile": 0.99999
}
07 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-07",
  "epss": 0.99999,
  "percentile": 0.99999
}
06 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-06",
  "epss": 0.99999,
  "percentile": 0.99999
}
06 Nov 2026, 18:20 Jerusalem · CVE Program record changed

Stored CNA snapshot at this observation.

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-109618",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-21T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2026-10-26",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
              },
              "type": "kev"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-28T03:55:46.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://www.wiz.io/blog/php2shell-php-rce"
          },
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
          },
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://php2shell.delftintellab.com"
          },
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2026-10-26T00:00:00.000Z",
            "value": "CVE-2026-109618 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2026-10-29T06:08:47.615Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
          },
          {
            "url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2026/Oct/51"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "AMIS TS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "AX4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "blueplanet 360 NX3 M6 WM OD IISX",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Building X",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "CADRA",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Call stations",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Capital",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Chargesight",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Climatix Cloud IC",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Climatix Devices",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Connect Insights",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Connect X200",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Connect X300",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Connect X500",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "cRSP",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Depotfinity",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter X",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter X Essentials",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo CC",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo DXR2",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo DXR3",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo Optic",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo PXC3",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo PXC4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo PXC5",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Desigo PXC7",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "DFMExpress",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Energy Engage V2.0SP9",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Energy Engage V3.1SP1",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Energy Management System",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Enlighted RTLS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Enlighted Space",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Heliox Flex Pro",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Heliox Flex Pro",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Heliox H60",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Heliox Rapid",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "HyperLynx",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Insights Hub",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Local Monitoring bt-monitoring-vm",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V20261103",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Navigator E&S",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Novigo VANSYS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Novigo VANSYS core",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Connect Electronics",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Connect MOM",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Core",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Discrete",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Foundation",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Pharma",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Process",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Intelligence",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Intra Plant Logistics",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Quality",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter RDnL",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter X",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PACE-Design",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Pro Essentials",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Pro Student Edition",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Professional",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Professional - XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Standard - XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Standard & Standard Plus",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Pathway to Learning Engineering",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Polarion",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "QuadView",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "RUGGEDCOM APE1808",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Sicharge D",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Sicharge D Configuration Backend",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SICHARGE FLEX",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SICHARGE UC",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Sifinity Control",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Sifinity Go",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Sifinity Setup",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Flomaster",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Flux",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Simlab",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Sinteso FS20 EN",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SiPass integrated",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIPORT",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Siveillance Control",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Siveillance Control Pro",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Siveillance Intrusion",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Siveillance Video",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Solid Edge",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Solid Edge",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 7",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power TG",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Supply Chain Suite",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Product Cost Management",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Share",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Visualization",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Tecnomatix Plant Simulation",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "TestWay",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Valor NPI",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Verischarge",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "VersiCloudHeliox Dual Port 60kW",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Voice alarm panels",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Voice alarm systems and audio matrices",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Workplace Experience",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xcargo",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Designer",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Enterprise",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Enterprise XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition IC Packaging",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Layout Browser",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-11-05T18:17:38.313Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
          },
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
          },
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "packageName": "php-src",
          "product": "PHP",
          "vendor": "PHP Group",
          "versions": [
            {
              "lessThan": "8.2.35",
              "status": "affected",
              "version": "8.2.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.3.36",
              "status": "affected",
              "version": "8.3.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.4.27",
              "status": "affected",
              "version": "8.4.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.5.12",
              "status": "affected",
              "version": "8.5.*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Ryan at Calif.io"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "Wiz"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "OpenAI"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Arnaud Le Blanc"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Ilija Tovilo"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Jakub Zelenka"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Nora Dossche"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).<br>"
            }
          ],
          "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-234",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-234 Hijacking a privileged process"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416 Use after free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-755",
              "description": "CWE-755 Improper Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of uninitialized pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1325",
              "description": "CWE-1325 Improperly controlled sequential memory allocation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1419",
              "description": "CWE-1419 Incorrect Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-21T13:48:34.845Z",
        "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "shortName": "php"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "RCE via OOM corruption",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "value": "Check the GitHub Security Advisory for mitigation strategies."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
    "assignerShortName": "php",
    "cveId": "CVE-2026-109618",
    "datePublished": "2026-10-21T13:48:34.845Z",
    "dateReserved": "2026-10-12T21:03:58.117Z",
    "dateUpdated": "2026-11-05T18:17:38.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}
06 Nov 2026, 06:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-05",
  "epss": 0.99999,
  "percentile": 0.99999
}
05 Nov 2026, 12:20 Jerusalem · CVE Program record changed

Stored CNA snapshot at this observation.

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-109618",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-21T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2026-10-26",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
              },
              "type": "kev"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-28T03:55:46.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://www.wiz.io/blog/php2shell-php-rce"
          },
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
          },
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://php2shell.delftintellab.com"
          },
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2026-10-26T00:00:00.000Z",
            "value": "CVE-2026-109618 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2026-10-29T06:08:47.615Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
          },
          {
            "url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2026/Oct/51"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "AX4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "CADRA",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Capital",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter X",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter X Essentials",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "DFMExpress",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "HyperLynx",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Insights Hub",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Connect Electronics",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Connect MOM",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Core",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Discrete",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Foundation",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Pharma",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Process",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Intelligence",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Intra Plant Logistics",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Quality",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter RDnL",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter X",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Pro Essentials",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Pro Student Edition",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Professional",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Professional - XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Standard - XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Standard & Standard Plus",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Pathway to Learning Engineering",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Polarion",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "QuadView",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "RUGGEDCOM APE1808",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Flomaster",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Flux",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Simlab",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Solid Edge",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Solid Edge",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Supply Chain Suite",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Product Cost Management",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Share",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Visualization",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Tecnomatix Plant Simulation",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "TestWay",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Valor NPI",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xcargo",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Designer",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Enterprise",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Enterprise XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition IC Packaging",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Layout Browser",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "AMIS TS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "blueplanet 360 NX3 M6 WM OD IISX",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Energy Engage V2.0SP9",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Energy Engage V3.1SP1",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 7",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power TG",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-11-04T17:47:39.617Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
          },
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
          },
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "packageName": "php-src",
          "product": "PHP",
          "vendor": "PHP Group",
          "versions": [
            {
              "lessThan": "8.2.35",
              "status": "affected",
              "version": "8.2.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.3.36",
              "status": "affected",
              "version": "8.3.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.4.27",
              "status": "affected",
              "version": "8.4.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.5.12",
              "status": "affected",
              "version": "8.5.*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Ryan at Calif.io"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "Wiz"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "OpenAI"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Arnaud Le Blanc"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Ilija Tovilo"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Jakub Zelenka"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Nora Dossche"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).<br>"
            }
          ],
          "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-234",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-234 Hijacking a privileged process"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416 Use after free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-755",
              "description": "CWE-755 Improper Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of uninitialized pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1325",
              "description": "CWE-1325 Improperly controlled sequential memory allocation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1419",
              "description": "CWE-1419 Incorrect Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-21T13:48:34.845Z",
        "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "shortName": "php"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "RCE via OOM corruption",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "value": "Check the GitHub Security Advisory for mitigation strategies."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
    "assignerShortName": "php",
    "cveId": "CVE-2026-109618",
    "datePublished": "2026-10-21T13:48:34.845Z",
    "dateReserved": "2026-10-12T21:03:58.117Z",
    "dateUpdated": "2026-11-04T17:47:39.617Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}
04 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-04",
  "epss": 0.99999,
  "percentile": 0.99999
}
03 Nov 2026, 18:20 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-03",
  "epss": 0.99999,
  "percentile": 0.99998
}
03 Nov 2026, 02:22 Jerusalem · EPSS observation updated

Stored EPSS snapshot at this observation.

{
  "date": "2026-11-02",
  "epss": 0.99999,
  "percentile": 0.99998
}
03 Nov 2026, 02:22 Jerusalem · CVE Program record changed

Stored CNA snapshot at this observation.

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-109618",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-21T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2026-10-26",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
              },
              "type": "kev"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-28T03:55:46.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://www.wiz.io/blog/php2shell-php-rce"
          },
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
          },
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://php2shell.delftintellab.com"
          },
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2026-10-26T00:00:00.000Z",
            "value": "CVE-2026-109618 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2026-10-29T06:08:47.615Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
          },
          {
            "url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2026/Oct/51"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "AX4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "CADRA",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Capital",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Designcenter X",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "DFMExpress",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "HyperLynx",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Insights Hub",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Connect Electronics",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Connect MOM",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Core",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Foundation",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Execution Pharma",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Intelligence",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Intra Plant Logistics",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter Quality",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter RDnL",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Opcenter X",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Pro Essentials",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Pro Student Edition",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Professional",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Professional - XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Standard - XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "PADS Standard & Standard Plus",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Polarion",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "QuadView",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "RUGGEDCOM APE1808",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Flomaster",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Flux",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Simcenter Simlab",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Solid Edge",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Solid Edge",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Supply Chain Suite",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Product Cost Management",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Teamcenter Visualization",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Tecnomatix Plant Simulation",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "TestWay",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Valor NPI",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xcargo",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Designer",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Enterprise",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Enterprise XCR",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition IC Packaging",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Xpedition Layout Browser",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "AMIS TS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "blueplanet 360 NX3 M6 WM OD IISX",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Energy Engage V2.0SP9",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Energy Engage V3.1SP1",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 4",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power 7",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "Spectrum Power TG",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-30T18:31:35.583Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
          },
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
          },
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "packageName": "php-src",
          "product": "PHP",
          "vendor": "PHP Group",
          "versions": [
            {
              "lessThan": "8.2.35",
              "status": "affected",
              "version": "8.2.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.3.36",
              "status": "affected",
              "version": "8.3.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.4.27",
              "status": "affected",
              "version": "8.4.*",
              "versionType": "semver"
            },
            {
              "lessThan": "8.5.12",
              "status": "affected",
              "version": "8.5.*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Ryan at Calif.io"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "Wiz"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "OpenAI"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Arnaud Le Blanc"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Ilija Tovilo"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Jakub Zelenka"
        },
        {
          "lang": "en",
          "type": "remediation developer",
          "value": "Nora Dossche"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).<br>"
            }
          ],
          "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-234",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-234 Hijacking a privileged process"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416 Use after free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-755",
              "description": "CWE-755 Improper Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of uninitialized pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1325",
              "description": "CWE-1325 Improperly controlled sequential memory allocation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1419",
              "description": "CWE-1419 Incorrect Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-21T13:48:34.845Z",
        "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "shortName": "php"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "RCE via OOM corruption",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "value": "Check the GitHub Security Advisory for mitigation strategies."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
    "assignerShortName": "php",
    "cveId": "CVE-2026-109618",
    "datePublished": "2026-10-21T13:48:34.845Z",
    "dateReserved": "2026-10-12T21:03:58.117Z",
    "dateUpdated": "2026-10-30T18:31:35.583Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}
03 Nov 2026, 02:22 Jerusalem · CISA KEV status changed

Stored KEV snapshot at this observation.

{
  "cveID": "CVE-2026-109618",
  "cwes": [
    "CWE-416",
    "CWE-755",
    "CWE-824",
    "CWE-1325",
    "CWE-1419"
  ],
  "dateAdded": "2026-10-26",
  "dueDate": "2026-10-29",
  "forensicTriage": "Yes",
  "knownRansomwareCampaignUse": "Unknown",
  "notes": "This vulnerability affects an open-source component, third-party library, protocol, or proprietary implementation that could be used by different products. For more information, please see: https://www.php.net/ ; https://www.cisa.gov/news-events/alerts/2026/10/21/critical-vulnerabilities-php-require-immediate-patching ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ;  https://nvd.nist.gov/vuln/detail/CVE-2026-109618",
  "product": "PHP",
  "requiredAction": "Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.",
  "shortDescription": "PHP contains an out-of-memory corruption vulnerability that allows for unauthenticated remote code execution.",
  "vendorProject": "PHP Group",
  "vulnerabilityName": "PHP Memory Corruption Vulnerability"
}
Egret — Back to top Egret